đ Electric Strike Failure After Break-In â What You Need to Know
- Alpha intercom broken
- Peso strike broken
- PESO STRIKE
- PESO STRIKE
- PESO STRIKE
- PESO STRIKE
- PESO STRIKE
đđ„ After a Break-In or Forced Entry â Why Electric Strikes Fail đ„đ
đ Montreal & Surrounding Areas â Shay Locksmith
After a break-in or forced entry, one of the most common failures we see is a damaged electric strike.
Todayâs intrusions are not always complex â in many cases, one strong pull on the door is enough to defeat low-quality hardware.
đ How Electric Strikes Actually Fail
Electric strikes are designed for convenience and controlled access, not as primary security against forced entry.
They resist force â but only up to a limit.
â ïž The key factor is DYNAMIC FORCE (impact/pull force) â not static rating.
âĄïž A fast, aggressive pull = instant failure on weak systems
â Important Warranty Notice
Electric strikes damaged by force, abuse, or break-in attempts are NOT covered under warranty.
đž LOW-COST ELECTRIC STRIKES ($200 and under)
âą â No warranty
âą âïž Weak internal components
âą đ„ Break easily under force
âą đ§ Not repairable â replacement required
đ Most common failure: Latch (lip) snaps off
đȘ UNDERSTANDING FORCE RATINGS (CRITICAL)
âą Standard/light-duty strikes: ~400 lbs resistance
âĄïž â One strong pull can break them
âą RCI U65 (commercial grade)
â ~800 lbs static
â ~70 ft-lb dynamic force
âą HES 1006 (heavy-duty)
â 3,000 lbs static
â 350 ft-lb dynamic
â Tested over 1,000,000 cycles
âą Adams Rite 7100 (single lip)
â 1,500 lbs static
â ~70 ft-lb dynamic
âą Adams Rite 7400 (dual/split lip)
â 1,500 lbs static
â ~70 ft-lb dynamic endurance
â 500,000 cycles
đ Reality: Even high-end strikes can release under strong pulling force â but they usually do NOT break.
đ ïž INSTALLATION MATTERS
When installing commercial strikes, alignment and flush fitting are critical:
âą Interlock plates / protection plates must be perfectly flat
âą Some models CANNOT be installed flush:
â HES 1006 â large latch (not flush possible)
â Adams Rite 7400 â limited cutting near latch
âą Others may be adjustable:
â RCI U65 â can be cut flush
â Adams Rite 7100 â possible, but not always perfect
â ïž Poor installation = increased vulnerability
đïž COMMERCIAL GRADE = REAL PROTECTION
âïž Stronger internal mechanisms
âïž Better resistance to forced entry
âïž Longer lifespan
âïž Reduced long-term costs
â ïž Note:
Upgrading may require frame modification and additional labor
đš MOST COMMON FAILED STRIKES WE SEE
âą Alpha (Montreal)
âą Peso (Germany)
âą RCI 15CA
đŠ SECURITY TIPS FOR BUILDING OWNERS
đŹ Encourage tenants to collect packages regularly
đ„ Upgrade cameras (8MP+ recommended)
đ Install cameras at:
âą Entrances
âą Mailboxes
âą Garages
âą Side doors
âą Floor access points
đš DONâT WAIT FOR THE NEXT BREAK-IN
Upgrade to a stronger, properly installed system and protect your building, tenants, and assets.
đ± 514-836-9097
đ§ info@serruriermontreal.com
đ Shay Locksmith â Security Done Right
đ Learn more:
https://serruriermontreal.com/%f0%9f%94%90-serrurier-shay-locksmith-maximum-security-for-your-building-%f0%9f%94%90/
â ïž Legal Notice / Avis lĂ©gal
All trademarks, brand names, and logos are the property of their respective owners.
No affiliation or endorsement is implied. Content provided for educational purposes only.
Toutes les marques de commerce, noms de marques et logos sont la propriété de leurs détenteurs respectifs.
Aucune affiliation ni approbation nâest impliquĂ©e. Informations fournies Ă titre Ă©ducatif uniquement.